Controllers for Electric Fire Pumps according to EN 12845 and UNE 23500
SCF830-E-U Star-delta Starting Fire Pump Controllers monitor, display and record Fire Pumps systems information. They are designed to meet and exceed the requirements of the EN 12845 and UNE 23500 standards.
SCF830-E-U controllers are high specification instruments and apply the most advanced technology in the starting and stopping process of Electric Fire Pumps. They protect the Fire Pumps through the action of the alarms both connected and generated by the controllers themselves; They manage the communication with the operator and with both the contour elements and the remote manned centre.
MAIN FEATURES: SCF830-E-U
Electric Fire Pumps Controllers: EN 12845, UNE 23500, LPC TB210, UNI 10779
Nº STANDARDS & TECHNICAL RULES 1 Standard EN 12845 Ed.2015 +A1:Ed. 2019 2 Standard UNE 23500 Ed.2018 & Ed.2012 3 Standard UNI 10779 Ed. 2014 4 Standard IEC 61439-1 Ed. 2011 Low-voltage switchgear and controlgear assemblies 5 Tech. Rule CEPREVEN R.T.1-ROC Ed.2004 6 Tech. Rule CEPREVEN R.T.2-ABA Ed.2006 Nº RANGE OF PRODUCTS (according to the type plate) 1 Incoming line voltage 600 V AC / 400 V AC / 230 V AC 2 Mains frequency 50 Hz / 60 Hz. 3 Main pump motor size Up to 400 kW (ask for other powers) 4 Jockey pump motor size Up to 30 kW 5 Motor starter type DOL / λ-Δ according to the motor power / Soft starters Nº CONSTRUCTIVE FEATURES 1 External enclosure IP65 Protected from total dust ingress (NEMA 4) 2 Impact rating: IK10 (except for display) 3 Fireproof grade: Fire extinguishes <30s 4 Display Transflective: Visible under direct sunlight 5 Wiring Halogen free 6 Fireproof: RZ1 according to EN50200 (830ºC for 90min) 7 Pump room temperature 20 ºF to 122ºF (-5ºC to 55ºC) 8 Isolation rating between phases 500 Vac 9 Isolation rating between phases and ground 2.500 Vac 10 Isolation impedance between phases and ground 2 MΩ 11 Earthing system TT system (neutral and earht connected separatelly ) 12 Electromagnetic environment CEM-1 Nº MEASURING INSTRUMENTS IN THE DISPLAY 1 System 3 Voltmeter: voltage for every phase R-S-T (RMS) 2 1 Mains frequency meter 3 1 pump rotation/phase rotation 4 1 Manometer pump discharge pressure ( pressure sensor required with 4-20 mA signal) 5 Main pump 1 Ammeter: pump current (RMS) 6 1 active power in KW (RMS) 7 1 Power factor (Cos φ) 8 1 Flowmeter: (flow sender required with 4-20 mA signal) 9 Jockey pump 1 Ammeter: pump current (RMS) 10 1 Active power in KW (RMS) 11 1 Power factor (Cos φ) 12 Controller 1 Voltmeter: Internal voltage 13 Controller 1 Voltmeter: back-up battery voltaje Nº PUMS & SYSTEM PROTECTION 1 Voltage loss 2 Normal power phase reversal 3 Normal frequency loss 4 Main pump protection trip 5 Overload main pump 6 Fail to start main pump 7 Jockey pump protection trip 8 Controller power loss 9 Low water reservoir tank 10 Low priming tank level 11 Battery charger failure 12 No internal battery detected 13 Low back-up battery voltage 14 Main pump pressure switch short circuit 15 Main pump pressure switch open circuit 16 Low power factor main pump 17 Low power factor jockey pump 18 Under-current main pump 19 Under-current Jockey pump 20 Overload Jockey pump 21 Pressure sensor fault 22 Driver fault main pump 23 Driver fault Jockey pump Nº COMMUNICATIONS & SIGNAL TRANSMISSION 1 micro USB Port Boot loader for firmware upgrading 2 SAF (control panel PLC ) configuration 3 PC monitoring: Pump and installation general condition 4 Pendrive data down-load: Events log / Pressures register log / Pump tests log 5 ETHERNET SAF (control panel PLC ) configuration 6 PC monitoring: Pump and installation general condition 7 RS485 SAF (control panel PLC ) configuration 8 PC monitoring: Pump and installation general condition 9 Voltage free contacts :
up to 30 V DC / 0,3 AVoltage loss 10 Main pump automatic mode OFF 11 Fail to start / not discharge pressure 12 Grouped alarmas 13 Pump on demand 14 Pump running with pressure Nº LANGUAGES & OTHER FEATURES 1 ENGLISH / ESPAÑOL / ITALIANO / FRANÇAIS / PORTUGUES 2 Monitored pressure switch lines: Short circuit / open circuit alarm 3 Pump demand by pressure transducer analog reading of system pressure 4 Jockey pump start count & working hours and minutes 5 Main pump working hours and minutes 6 500 last events log (starts, alarms, …) 7 16,000 latest records of system pressure variation 8 50 pressure / Flow pump test récords 9 Current date and time (RTC with independent battery) 10 Calibration of analog measurements: Pressure / Voltage / Amps … 11 Digital and analog inputs and outputs checking of on the display 12 80 dB buzzer