Controllers for Electric Fire Pumps according to EN 12845 and UNE 23500
SCF830-E(VS)-U Solid State Starting Fire Pump Controllers monitor, display and record Fire Pumps systems information. They help to reduce water hammer in the system and are designed to meet and exceed the requirements of the EN 12845 and UNE 23500 standards.
SCF830-E(VS)-U controllers are high specification instruments and apply the most advanced technology in the starting and stopping process of Electric Fire Pumps. They protect the Fire Pumps through the action of the alarms both connected and generated by the controllers themselves; They manage the communication with the operator and with both the contour elements and the remote manned centre.
MAIN FEATURES: SCF830-E(VS)-U
Electric Fire Pumps controllers: EN 12845
Nº |
RANGE OF PRODUCTS (according to the type plate) |
1 |
Incoming line voltage |
600 V AC / 400 V AC / 230 V AC |
|
2 |
Mains frequency |
50 Hz / 60 Hz. |
|
3 |
Main pump motor size |
Up to 400 kW (ask for other powers) |
|
4 |
Motor starter type |
Soft Starter / Variable Frequency Drives (VFD) |
|
Nº |
CONSTRUCTIVE FEATURES |
1 |
External enclosure |
IP65 Protected from total dust ingress (NEMA 4) |
2 |
Impact rating: IK10 (except for display) |
3 |
Fireproof grade: Fire extinguishes <30s |
4 |
Display |
Transflective: Visible under direct sunlight |
5 |
Wiring |
Halogen free |
6 |
Fireproof: RZ1 according to EN50200 (830ºC for 90min) |
7 |
Pump room temperature |
20 ºF to 122ºF (-5ºC to 55ºC) |
8 |
Isolation rating between phases |
500 Vac |
9 |
Isolation rating between phases and ground |
2.500 Vac |
10 |
Isolation impedance between phases and ground |
2 MΩ |
11 |
Earthing system |
TT system (neutral and earht connected separatelly ) |
12 |
Electromagnetic environment |
CEM-1 |
Nº |
MEASURING INSTRUMENTS IN THE DISPLAY |
1 |
System |
3 Voltmeter: voltage for every phase R-S-T (RMS) |
|
2 |
1 Mains frequency meter |
|
3 |
1 pump rotation/phase rotation |
|
4 |
1 Manometer pump discharge pressure ( pressure sensor required with 4-20 mA signal) |
|
5 |
Main pump |
1 Ammeter: pump current (RMS) |
|
6 |
1 active power in KW (RMS) |
|
7 |
1 Power factor (Cos φ) |
|
8 |
1 Flowmeter: (flow sender required with 4-20 mA signal) |
|
9 |
Controller |
1 Voltmeter: Internal voltage |
|
10 |
Controller |
1 Voltmeter: back-up battery voltaje |
|
Nº |
PUMS & SYSTEM PROTECTION |
1 |
Voltage loss |
2 |
Normal power phase reversal |
3 |
Normal frequency loss |
4 |
Main pump protection trip |
5 |
Overload main pump |
6 |
Fail to start main pump |
7 |
Controller power loss |
8 |
Low water reservoir tank |
9 |
Low priming tank level |
10 |
Battery charger failure |
11 |
No internal battery detected |
12 |
Low back-up battery voltage |
13 |
Main pump pressure switch short circuit |
14 |
Main pump pressure switch open circuit |
15 |
Low power factor main pump |
16 |
Under-current main pump |
17 |
Under-current Jockey pump |
18 |
Pressure sensor fault |
19 |
Drive fault main pump |
Nº |
COMMUNICATIONS & SIGNAL TRANSMISSION |
1 |
micro USB Port |
Boot loader for firmware upgrading |
2 |
SAF (control panel PLC ) configuration |
3 |
PC monitoring: Pump and installation general condition |
4 |
Pendrive data down-load: Events log / Pressures register log / Pump tests log |
5 |
ETHERNET |
SAF (control panel PLC ) configuration |
6 |
PC monitoring: Pump and installation general condition |
7 |
RS485 |
SAF (control panel PLC ) configuration |
8 |
PC monitoring: Pump and installation general condition |
9 |
Voltage free contacts :
up to 30 V DC / 0,3 A |
Voltage loss |
10 |
Main pump automatic mode OFF |
11 |
Fail to start / not discharge pressure |
12 |
Grouped alarmas |
13 |
Pump on demand |
14 |
Pump running with pressure |
Nº |
LANGUAGES & OTHER FEATURES |
1 |
ENGLISH / ESPAÑOL / ITALIANO / FRANÇAIS / PORTUGUES |
|
2 |
Monitored pressure switch lines: Short circuit / open circuit alarm |
|
3 |
Pump demand by pressure transducer analog reading of system pressure |
|
4 |
Main pump working hours and minutes |
|
5 |
500 last events log (starts, alarms, …) |
|
6 |
16,000 latest records of system pressure variation |
|
7 |
50 pressure / Flow pump test récords |
|
8 |
Current date and time (RTC with independent battery) |
|
9 |
Calibration of analog measurements: Pressure / Voltage / Amps … |
|
10 |
Digital and analog inputs and outputs checking of on the display |
|
11 |
80 dB buzzer |
|
Nº |
IDIOMAS / OTRAS FUNCIONES |
1 |
ESPAÑOL / ENGLISH / ITALIANO / FRANÇAIS / PORTUGUES |
2 |
Estado presostatos: Vigilancia corto circuito / circuito abierto |
3 |
Medidor de presión de sistema: Muestra en pantalla: Tarado niveles de demanda y stop |
4 |
3 modos de funcionamiento: OFF/ MAN / AUTO: bloqueable con llave |
5 |
Registro de eventos: Histórico de 500 eventos en memoria: Descargables a pendrive |
6 |
Registro de presiones: Histórico de 16.000 registros en memoria: Descargables a pendrive |
7 |
Registros de prueba de bomba: Histórico de 50 pruebas en memoria: Descargables a pendrive |
8 |
Indicación número de arranques + Horas y minutos bomba Jockey |
9 |
Indicación número de horas de funcionamiento bomba Principal |
10 |
Indicación display de estados de entradas y salidas, digitales y analógicas |
11 |
Elementos de potencia: Contactores en AC-3 / Interruptores en AC-23 |