FIRE FIGHTING

SCF122-DI

DISCONTINUED
SCF122-DI

Controllers for Diesel Fire Pumps according to EN 12845 and UNE 2300

SCF122-DI are designed to meet and exceed the requirements of the EN 12845 and UNE 23500 standard; They are high specification instruments that apply the most advanced technology. They offer unrivalled features such as communications,  configurations, versatility and robustness.

SCF122-DI controllers govern the starting and stopping process of the Diesel Fire Pumps and protect them through the action of the alarms both connected and generated by the controller itself; they visualise the most relevant values and information, also manage the communication with the operator and with both the contour elements and the remote manned centre

MAIN FEATURES: SCF122-DI

Diesel engine Fire Pumps controllers: EN 12845 and UNE 2300

  • STANDARDS & TECHNICAL RULES
    1 Standard EN 12845 Ed.2015
    2 Standard UNE 23500 Ed.2012
    3 Standard UNI 10779 Ed. 2014
    4 Standard IEC 61439-1 Ed. 2011 Low-voltage switchgear and controlgear assemblies
    5 Tech. Rule CEPREVEN R.T.1-ROC Ed.2004
    6 Tech. Rule CEPREVEN R.T.2-ABA Ed.2006
  • RANGE OF PRODUCTS (according to the type plate)
    1 Nominal supply voltage 230 V AC
    2 Nominal frequency 50Hz / 60Hz.

     

    RANGE OF PANELS ACCORDING TO BATTERY CHARGERS  SCF122-DI 12070 SCF122-DI 12100 SCF122-DI 24035 SCF122-DI 24050
    Nominal Voltage 12 V DC 12 V DC 24 V DC 24 V DC
    Rated Amp 7 A 10 A 3,5 A 5 A
    DIN Power 96,6 W 138,0W 96,6 W 138,0 W
    Capacity of the batteries (C10) 200 Ah 285 Ah 100 Ah 142 Ah
  • CONSTRUCTIVE FEATURES
    1 Enclosure Ingress protection rating: IP65
    2 Protection against impacts degree: IK10 except PLC IGNIMATIC D122
    3 Fireproof degree: The fire is extinguished in <30s with dripping
    4 Display LCD 4 lines / 20 characters
    5 Cabling Free of halogens
    6 Fire resistance: RZ1 according to EN50200 (Max: 830º / 90min)
    7 Working temperatures From -5ºC to 50ºC
  • MEASURING INSTRUMENTS IN THE DISPLAY
    1 Batteries 2 Voltmeter: Battery voltage
    2 2 Ammeter: Battery charging Amp
    4 1 Battery equalization timer
    5 Engine 1 Fuel tank level meter
    6 1 Oil pressure gauge (sensor not included)
    7 1 Engine temperature thermometer (sensor not included)
    8 1 Engine speed meter (sensor not included)
  • PUMP & SYSTEM PROTECTION
    1 System not in autamatic mode
    2 Mains failure
    3 Engine over-speed
    4 Low oil pressure
    5 High engine temperature
    6 Low fuel level
    7 Battery A low voltage
    8 Battery B low voltage
    9 Loss of charger A protection
    10 Loss of charger B protection
    11 Heater overload tripped
    12 Bendix voltage fail
    13 Fail to start
    14 Discharge pressure fail
    15 Low reservoir tank
    16 Low priming tank
    17 Pick-up fault
  • 1 RS485 port (Optional) IGNIMATIC D122 controller configuration
    2 PC monitoring: Pump and installation general condition
    3 Ethernet port (Optional) IGNIMATIC D122 controller configuration
    4 PC monitoring: Pump and installation general condition
    5 Voltage free contacts :
    up to 30 V DC / 0,3 A
    Power not available
    6 Automatic mode Off
    7 Fail to start / not discharge pressure
    8 Grouped alarms
    9 Pump on demand
    10 Pump running with pressure
  • LANGUAGES / OTHER FEATURES
    1 ENGLISH/ ESPAÑOL / ITALIANO / FRANÇAIS / PORTUGUES
    2 Engine heating management via temperature reading probe
    3 Engine hours
    4 Engine coolant circuit management
    5 Buzzer: 80dB
    6 Event historical: Last 47 events