SCF122-DI 12030 control panels are small, automatic and configurable instruments, useful for managing operations of small diesel engine driven fire-fighting pumpsets in any environment.
They govern the start and stop of the diésel engine driven fire-fighting pumpsets and protect them by means of the action of the connected and controller-generated alarms, visualize the most relevant values and informations also manage the communication with the operator and both the contour elements and the remote manned centre.
MAIN FEATURES: SCF122-DI 12030
Diesel engine Fire Pumps controllers: EN 12845 / 23500
Nº STANDARDS & TECHNICAL RULES 1 Standard EN 12845 Ed.2015 2 Standard UNE 23500 Ed.2012 3 Standard UNI 10779 Ed. 2014 4 Standard IEC 61439-1 Ed. 2011 Low-voltage switchgear and controlgear assemblies 5 Tech. Rule CEPREVEN R.T.1-ROC Ed.2004 6 Tech. Rule CEPREVEN R.T.2-ABA Ed.2006 Nº RANGE OF PRODUCTS (according to the type plate) 1 Nominal supply voltage 230 V AC 2 Nominal frequency 50Hz / 60Hz. 3 Battery chargers 12 V DC / 3 A 4 Capacity of the batteries ( C10 ) 85 Ah Nº CONSTRUCTIVE FEATURES 1 Enclosure Ingress protection rating: IP65 2 Protection against impacts degree: IK10 except PLC IGNIMATIC D122 3 Fireproof degree: The fire is extinguished in <30s with dripping 4 Display LCD 4 lines / 20 characters 5 Cabling Free of halogens 6 Fire resistance: RZ1 according to EN50200 (Max: 830º / 90min) 7 Working temperatures From -5ºC to 50ºC Nº MEASURING INSTRUMENTS IN THE DISPLAY 1 Batteries 2 Voltmeter: Battery voltage 2 2 Ammeter: Battery charging Amp 4 1 Battery equalization timer 5 Engine 1 Fuel tank level meter 6 1 Oil pressure gauge (sensor not included) 7 1 Engine temperature thermometer (sensor not included) 8 1 Engine speed meter (sensor not included) Nº PUMP & SYSTEM PROTECTION 1 System not in autamatic mode 2 Mains failure 3 Engine over-speed 4 Low oil pressure 5 High engine temperature 6 Low fuel level 7 Battery A low voltage 8 Battery B low voltage 9 Loss of charger A protection 10 Loss of charger B protection 11 Heater overload tripped 12 Bendix voltage fail 13 Fail to start 14 Discharge pressure fail 15 Low reservoir tank 16 Low priming tank 17 Pick-up fault 1 RS485 port (Optional) IGNIMATIC D122 controller configuration 2 PC monitoring: Pump and installation general condition 3 Ethernet port (Optional) IGNIMATIC D122 controller configuration 4 PC monitoring: Pump and installation general condition 5 Voltage free contacts :
up to 30 V DC / 0,3 APower not available 6 Automatic mode Off 7 Fail to start / not discharge pressure 8 Grouped alarms 9 Pump on demand 10 Pump running with pressure Nº LANGUAGES / OTHER FEATURES 1 ENGLISH/ ESPAÑOL / ITALIANO / FRANÇAIS / PORTUGUES 2 Engine heating management via temperature reading probe 3 Engine hours 4 Engine coolant circuit management 5 Buzzer: 80dB 6 Event historical: Last 47 events