Controllers for Diesel Fire Pumps according to NFPA 20
SCF830-D-N are designed to meet and exceed the requirements of the NFPA 20 standard; They are high specification instruments that apply the most advanced technology. They offer unrivalled features such as communications, configurations, versatility and robustness.
SCF830-D-N controllers govern the starting and stopping process of the Diesel Fire Pumps and protect them through the action of the alarms both connected and generated by the controller itself; they visualise the most relevant values and information, also manage the communication with the operator and with both the contour elements and the remote manned centre.
MAIN FEATURES: SCF830-D-N
Diesel engine Fire Pumps controllers: NFPA 20
Nº STANDARDS & TECHNICAL RULES 1 Standard NFPA 20 2 Standard NFPA 70 3 Standard IEC 61439-1 Ed. 2011 Low-voltage switchgear and controlgear assemblies Nº RANGE OF PRODUCTS (according to the type plate) 1 Nominal supply voltage 230 V AC 2 Nominal frequency 50Hz / 60Hz. RANGE OF PANELS ACCORDING TO BATTERY CHARGERS SCF830-D-U 12070 SCF830-D-U 12100 SCF830-D-U 24050 Nominal Voltage 12 V DC 12 V DC 24 V DC Rated Amp 7 A 10 A 5 A DIN Power 96,6 W 138,0W 138,0 W Capacity of the batteries (C10) 200 Ah 285 Ah 142 Ah Nº CONSTRUCTIVE FEATURES 1 Enclosure Ingress protection rating: IP65 2 Protection against impacts degree: IK10 except PLC SAF830-D-U 3 Fireproof degree: The fire is extinguished in <30s with dripping 4 Display Graphic / Transflective 5 Cabling Free of halogens 6 Fire resistance: RZ1 according to EN50200 (Max: 830º / 90min) 7 Working temperatures From -5ºC to 50ºC Nº MEASURING INSTRUMENTS IN THE DISPLAY 1 Batteries 2 Voltmeter: Battery voltage 2 2 Ammeter: Battery charging Amp 4 1 Battery equalization timer 5 Engine 1 Fuel tank level meter 6 1 Oil pressure gauge (sensor not included) 7 1 Engine wáter thermometer (sensor not included) 8 1 Engine oil thermometer (sensor not included) 9 1 Engine speed meter (sensor not included) 10 System 1 System pressure meter (sensor not included) 11 1 Flow meter ( manual introduction / 4⁄20mA sender not included) 12 1 Voltmenter AC V supply voltaje Nº PUMP & SYSTEM PROTECTION 1 MAINS FAILURE 2 OVER SPEED 3 LOW OIL PRESSURE 4 HIGH WATER ENGINE TEMPERATURE 5 LOW FUEL LEVEL 6 LOW BATTERY A VOLTAGE 7 LOW BATTERY B VOLTAGE 8 CHARGER A FAULT 9 CHARGER B FAULT 10 HEATER PROTECTION TRIPPED 11 CRANK ENGINE VOLTAGE FAIL 12 FAILED TO START 14 LOW RESERVOIR TANK 16 SPEED SIGNAL FAULT 17 PRESSURE SWITCH SHORT-CIRCUIT 18 PRESSURE SWITCH OPEN-CIRCUIT 19 MAINS FREQUENCY FAIL 20 COMMUNICATION FAIL 21 ECM ALTERNATIVE POSITION 22 FUEL INJECTION 23 ECM WARNING 24 ECM FAULT 25 LOW SUCTION PRESSURE 26 HIGH RAW WATER TEMPERATURE 27 LOW RAW WATER FLOW 28 HIGH FUEL LEVEL 29 FUEL TANK LEAK 30 CRANKING LEVERS FAULT 31 LOW COOLANT TEMPERATURE 32 DC VOLTAGE FAIL 33 HIGH BATTERY A VOLTAGE 34 HIGH BATTERY B VOLTAGE 35 BATTERY A DEFECTIVE 36 BATTERY B DEFECTIVE 37 WATER PRESSURE SENSOR FAULT 38 TEST FAILURE 1 Device: USB connector type B Communication SAF830-D<—> PC 2 Host: USB connector type Communication SAF830-D<—> Pendrive (external memory) 3 Ethernet port (TCP/IP) PC monitoring: Pump and installation general condition 4 RS 485 port (Optional) PC monitoring: Pump and installation general condition 5 Voltage free contacts :
up to 270 V AC / 5 ADELAYED COOLANT 5 LOW FUEL LEVEL 7 FAILED TO START 8 PUMP ON DEMAND 9 AUTO START INHIBITED 10 PUMP RUNNING 11 COMMON ALARM Nº LANGUAGES / OTHER FEATURES 1 ESPAÑOL / ENGLISH / ITALIANO / FRANÇAIS / PORTUGUES 2 Monitored pressure switch lines: Short circuit / open circuit alarm 3 Monitored connection solenoid box. Cranking levers fault alarm 4 Pump demand by pressure transducer analog reading of system pressure 5 Current date and time (RTC with independent battery) 6 500 last events log (starts, alarms, …) 7 16,000 latest records of system pressure variation 8 50 pressure / Flow pump test récords 9 Calibration of analog measurements: Pressure / Voltage / Temperature … 10 Digital and analog inputs and outputs checking of on the display 11 Accumulate engine operations hours and minutes 12 Engine cooling circuit management 13 Engine heating resistence management 14 Pressure transducer included 15 Electro drain valve included